Using tin snips, snip off the thin 18 gauge metal strip be-tween the two element slots to allow the 15--20 kW heater elements to slip in as one piece (see Fig. Jul 25, 2006 · Had a new Trane heat pump air handler installed today with 8 KW heat strips. 0 kW 08 8. Share: Nov 4, 2021 · Electric Water Heater Tune-Up Kit, Includes Two 4500W 240V Water Heater Elements, Upper Thermostat, Lower Thermostat, Two Protective Covers, Two Elements Gaskets Feb 4, 2024 · From the chart, we can determine that: a 2. $ 139. 5kW for 9. We would like to show you a description here but the site won’t allow us. 5 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. 8417 for possible Nordyne 917173C Heat Kit w/ Breakers 20kw FurnacePartSource. The most widely used sizes are 5, 7. Two 3 kW heat strips would be practical to handle the Aux Heat down to 10'F with a 2-ton 10 HSPF rated heat pump. Apr 19, 2024 · – 5 kW – 7 kW – 10 kW. www. 6 7 ratings. Jan 18, 2018 · The 35 amp fuses at the control box keep blowing up. Nordyne 904416 Heat Strip Kit 20Kw If out of stock, call or text 1. I will say that you must have a wire with an ampacity of at least 52. The Goodman HKP Series Heat Strip have rust resistant nickel chromium heat elements. DO NOT SNIP OFF METAL FOR 5--10 kW heaters. 56 Amps for that 4Sqmm copper Cable The 9. 1. 60 kW 10 9. Dec 5, 2023 · The winter chill prompts many homeowners to evaluate their heating options, and heat strips play a crucial role in HVAC systems. Heating Capacity: 30,001 BTU/H - 35,000 BTU/H. ‡ Field convertible to 1 phase, single or multiple supply circuit. com: Tools & Home Improvement Each Kw produces about 3400 Btu's of heat, so the heating output of the various heat strip options are as follows. 99 $ 129. 5 kW * 1000 is 5 MW, not 5000 W. I'm pretty sure that the tech support guy said that I'd need a 50A breaker for it and I didn't realize until recently that it actually calls for a 60A breaker. Lennox ECBA25-12. Is that accurate? Just want to make sure. 0 tons Heat Pump - Use a 5 Kw 2. Jan 7, 2013 · a 15K heater pack is actually 3 - 5 K heat strips it's all in how it's wired. 5CB Jan 3, 2013 · I haven't wired up a 20 kw in years. I'll wire the compressor using #6-2 thru 60 amp breaker, and I saw some posting suggesting #6 wire for the air handling Note. If p. ) On fan coil units size 042 and larger, remove wire tie that shortens wire length between heater and circuit breaker assembly to allow mounting of circuit breaker assembly. In the above formulas: Power factor (p. Free shipping on orders over $99 Your Zip: 98837 Jan 22, 2021 · 20 kW Rheem/RUUD # RXBH-24A20J Electric Strip Heater Kit with Breaker: Amazon. 120 Volt heaters require 1-Pole circuit breakers; 240 Volt heaters need 2-Pole breakers. 5 Kw Ruud Electric Strip Heat Kit with Circuit Breaker is available to buy in increments of 1 Ruud 7. The maximum safe current limit is 80% of the rated size of breaker except some motors. Below is the given chart showing the % of max current rating of breaker size for different types of load currents. 6 kw and that the existing #4 aluminum wire I have is sufficient to carry the amperage required of the 9. (For example: 2-1000W & 1-1500W, 240V heaters = 3500 Watts total. 8 0. Is this common practice? I cannot find 4/2 wire ANYWHERE Goodman 20 Kw Electric Strip Heat Kit with Circuit Breaker is available to buy in increments of 1 Goodman 20 Kw Electric Strip Heat Kit with Circuit Breaker Model Oct 28, 2022 · 60 Amp 20kW = 20000W. 5 kW G Three Phase 460 V* 06 6. Furnace Btu size calculator. 95 Original price was: $199. Features: Can generally support up to an average-sized house (in ideal conditions) 10 kW heat kit, providing an output of 32,000 BTU; Requires one 60 amp breaker; Prevents hot spots to extend heater life 3. 3333 amps only, and would, therefore, need only Jan 25, 2019 · Goodman HKSC20DA Air Handlers Electric Heat Kit ; Circuit Breaker ; Heating: 0 BTU 20 kW, Cooling: 0 BTU, 208 V 1 Phase ; Register your new Goodman unit for enhanced warranty coverage at no cost. 5 tons Heat Pump - Use a 15 Kw 4. Provides Emergency Heat for your MRCOOL Universal Air Handler. MrCool 20kW Heat Strip w/ Circuit Breaker for Universal Air Handler. 10kW Electric Heat Kit for Bosch Air Handler - WARMEHK100B • Ingrams Water & Air Nov 13, 2022 · I'm just getting around to installing the 10 KW add-on heat strip (BPHK10BP-1). 95 Original price was: $169. 00 Pre-tested, pre-wired heat kits 1 phase models. Above all Goodman HKA-20C 20kW Heating Element With Breaker ">Model Number HKA-20C Electric Heat Strips. A #10 copper wire with an insulation rating of 90 degrees C is rated at 30 amps. Dec 28, 2020 · It came with a 50' pigtail with a 60 amp breaker at the end of it which I installed into my panel at the power pole. Having two breakers is still not a problem. Colder winter climates (Average low winter temperatures of 0 degrees and up) 1. 5 kW Heat Strip with Circuit Breaker for 1. I don't have my book handy, so I don't know if a #8 will suffice. Visit the Goodman Store. It features rust-resistant nickel chromium heat elements, plug-in wiring harness for air handler installation ease, fuse link secondary high-temperature limit protection, a control circuit View and Download Trane OXBOX J4AH4P Series installation instructions manual online. But NEC 210. 8 amps if wired to a 240 volt circuit. This 240 volt heater coil can be added to a Goodman air handler to provide winter-time heating capabilities. HNRd10-D Heat Kit is the compatible heat kit model for MRCOOL MDUI18024 and MDUI18036. -Sale! HEAT STRIP With Breaker 8KW FOR ICP, Carrier, Bryant, Payne AIR HANDLE $ 199. If the load is over 60 amps then the load must be split up. 50 kW * A 1 2 3 4,5 11 HKR * -­‐05 Unit Type Revisions HKS Heat Kit for Engineering Revisions Air Handlers Phase Phase A Single Phase 208 V X No circuit breaker B Single Phase 240 V C Circuit Breaker C Single Phase 208/240 V D Three Phase The CPHEATER126A03 is a 5 kW heat kit designed to work with ACiQ packaged units. 3 4. Oct 2, 2023 · For example, a 8kW heat strip at 240 volts will demand a 45-amp breaker, while the same heat strip that comes at 208 volts would need a 40-amp one. 5Kw heat strips typically are installed with 240v supply voltage and pull at most 20a. The distance of the wire is about 15 feet. 5 - 3. If I remember right, a couple of the ones I wired had a 60 amp 2 pole and 2 - 30 amp 2 pole breakers. Credit: www. Definition of Heat Strips Heat strips, also known […] Budget Heating & Air has access to thousands of heat strips ranging from 3 kW to 25 kW, single phase and with or without breakers. Air Handler use 1 MHK05U Circuit Breaker,5kW Heat Strip MDUI18024,36 2 MHK08U Circuit Breaker,8kW Heat Strip MDUI18024,36 3 MHK10U Circuit Breaker,10kW Heat Strip MDUI18036 4 MHK15U Circuit Breaker,15kW Heat Strip MDUI18048,60 5 MHK20U Circuit Breaker,20kW Heat Strip MDUI18048,60 Elevate your comfort with the MRCOOL 20KW Auxiliary Heat Kit, designed exclusively for MRCOOL Central series Air Handlers. What size breaker and wire gauge is required for a 10kw heat strip. Use 2-wire cable with ground (Romex™ or BX). Please contact us for commercial, three phase applications not listed. Cat # : 12S87 Model/Part # : ECB25-15CB-2P Jun 30, 2012 · Buy 8 Kw Goodman / Amana Electric Strip Heater With Circuit Breaker - HKR-08C by Amana/Goodman: Goodman HKSX10XC 10 kW 208/240 V 1 Phase Electric Heat Kit. Most air handlers with 15 KW of strip heat. The Goodman HKSC15XB SmartFrame 15k 240V Heat Strip might be exactly what you've been Googling to find. supercoolsliderule. York S1-2HK16502506 - 25KW Heat Strip Kit w/ Breaker (240V), S1-2HK16502506- S1-2HK16502506 Is an official OEM replacement part for York HVAC equipment. Controlled by sequencers for optimum temperature balance. The tech installed the 10kw for a temporary heat source and came back the next day and installed the 7kw heat strip. 6 amps, which is 52 amps. Sep 16, 2023 · 10 kW at 220v will use 45. 4 — Snip Metal (18 gage) Strip for 15 or 20Kw Jan 19, 2023 · The breaker size for a 20kW heat strip would typically be around 60 amps, as the maximum fuse breaker for this type of device is typically 60 amps. For single-phase installation, a minimum 100-amp breaker is needed to support 20 kW. Max Fuse Breaker: 60 Amp. $24100. MRCOOL Heat Kit is the compatible heat kit model for MRCOOL MDUI18024 and MDUI18036. . HNRd8-D Heat Kit is the compatible heat kit model for MRCOOL MDUI18024 and MDUI18036. * Indicates medium speed (blue). A 5kw or 5,000 watt heat strip will use 20. BudgetHeating. Features: Can generally support up to a small house (in ideal conditions) Requires one 30 amp breaker to function Jun 23, 2015 · So I have this question regarding how to wire up the heat package. - May 24, 2022 · But neither the installation instructions nor the submittals specify the breaker or wire size for the 15kW backup heat unit. 4 kW 208 V 1 Phase Electric Heat Kit w/Circuit Breaker. 0 kW Cabinet Size (MAX) 10 9. 6 kw. com Efficiency And Electricity Usage. Oct 27, 2008 · trying to remember--does anyone know off hand how many amps a 15 kw heater would pull on a goodman split heat pump,i couldnt remember how many and if it would take 2 power sources or just one,the size of the breaker and the size of the wire if just one was used,right now there is a number 6 wire pulled and i was putting in a 4-ton split goodman heat pump--but was debating on 10kw or 15kw--the May 15, 2024 · Goodman HKS 20 kW Electric Heat Kit For ARPT, ARUF, ASPT, AVPTC Open To Public Call Today 1-888-292-0874! Goodman HKS 20 kW Heat Kit HKSC19CB. Same question 10kw heat strip and a 15kw heat strip. Keep in mind that the breaker size should not increase the max amperage rating of cable and wire. Experience uninterrupted warmth with 20KW of reliable backup heating at your fingertips. Please note that this item requires one 30 amp breaker to function, and that it cannot operate independently from a compatible ACiQ unit. I have a 2. com Page 6 Kit# Description Ref. ableroof. It is 15kw with a 60amp [COLOR=blue !important][COLOR=blue !important]breaker [/COLOR][/COLOR] and a 30 amp breaker. Based on these readings, I know I need at least a 45amp fuses. 20 requires overcurrent for continuous load to be no less than 125% of full load current. Heating Capacity: 65,001 BTU/H - 70,000 BTU/H. 6A) With all that said is it all right to run a #4THHN and install 90A Fuses. I'd recommend a 60A circuit, with a 60A breaker, but the heater or electric furnace should have "maximum fuse amps" rated on its nameplate. Cat # : 16Y42 Model/Part # : ECBA25-10CB If the breaker is visibly damaged, then replace the breaker. 2A, for a total of 62. 000000: Brand/Manufacturer: MRCOOL: Electric Heat: 10 Kilowatts: Electrical: 208/230v 1 Phase 60 Hz: Phase: Single Phase: Max Breaker Size: 60 amps: Safety Information: PROPOSITION 65 WARNING Home > Heat Strip Electric > Rheem Heat Strips > 20 KW breakered heat strip for Rheem RH1, RH2, RHL, RHS, RHP RXBH-1724A20J WRX2002B Alternative Views: List Price: $284. Approved for manufactured or modular homes. 2 kW with 170F limit 25 25. Goodman 20 Kilowatt 68,200 BTU Heat Strip Air Conditioner Package Unit - HKP-20C | HVACDirect. 5 - 5. 9 out of 5 Customer Rating. $129. HIGH EFFICIENCY AIR HANDLERS. I measured the amperage coming in from the panel, I have around 41 amps. 620. These standard sizes cater to a variety of home sizes and heating demands. Jan 18, 2024 · Alternatively, a wire-breaker size chart may provide the same information. Is this correct? Jun 14, 2009 · These units get two circuits, im questioning the heating circuit. Also, the correct units is kW (killo-Watts), not KW (Kelvin-Watts)). 6 kw requires 54. Choosing the Right Heat Strip Size for Your Home. Nov 12, 2013 · You co-worker is right in calculating the current per element. The 10 kW strip would be on the 60A breaker, and probably everything else in the air handler -- the 5 kW strip, the blower, and the low voltage -- are on the 30A breaker. The HNRD20-D is capable of 65,001 - 70,000 BTU of heating capacity to keep you comfortable through the winter months. com Dec 12, 2017 · 10 KW Goodman Heat Strip with Breaker for ARUF, MBR, MBVC Air Handlers # HKR-10C . 5CB, 12. When placing multiple heaters on a circuit do not exceed the wattage listed for the corresponding wire and circuit breaker size. Its single stage 40 amp, I have a double pole 60 in the box. 6 0. All necessary limit controls with circuit breakers; Heat Strip Size: 20 kW : Product Width (in) 9 : Max Overcurrent Protection: 60/50 amps : Weight (lbs) 12. A #8 copper wire with an insulation Dec 19, 2019 · What size breaker do I need for a 15 KW furnace? Administrator. You already have all the knowledge you need to use the breaker size Lennox ECB25-15CB-2P, 15 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. Getting new Trane HVAC with 10 kw heat strip. All other motor speeds at low tap. Generally, the 8KW heat strip takes a 220 volt and 40 amp breaker. You can use a 60 amp breaker on such a wire, since it is the next higher rated overcurrent device. But that was probably 12 years ago. Free shipping on orders over $99 Your Zip: 23917 Breaker None Single-­‐ or 3-­‐Phase Kit; Phase No Circuit Breaker None Single-­‐Phase C Single-­‐Phase Kit w/ 3 Three-­‐Phase Circuit Breaker Hea8ng Capacity @ 240 Volts 5 4. For instance, if you have a room of 200 square feet that requires a heat load of 10 BTU/hr per square foot, the calculator will use the formula to give a heat strip size of 2000 BTU/hr. 9A 75deg. Voltage. 5. 1 0. While your MRCOOL Central system is engineered for impeccable performance, this heat kit offers you peace of mind, ensuring you're never left out in the cold. Elevate your comfort with the MRCOOL 10KW Auxiliary Heat Kit, designed exclusively for MRCOOL Central series Air Handlers. (See Fig. This tutorial will teach you how to properly size your wire for electric heat strips using the SuperCool Slide Rule. 5 ton heat pump breaker size is about 20 to 30 amps; a 3 ton heat pump breaker size is also typically about 20 to 30 amps 15 KW Universal Air Handler Heat Strip with Circuit Breaker Prop65 Important PROP 65 Information Warning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. 0 tons Heat Pump - Use a 10Kw. Jan 15, 2012 · My guess is that, if it is in fact a 15 kW system (and it may be, with a heat pump of that size), it has a 10 kW heat strip and a 5 kW strip, perhaps staged in some fashion. 1 Phase. The HNRD15-D is capable of 50,001 - 55,000 BTU of heating capacity to keep you comfortable through the winter months. 000000 : May 16, 2024 · Tutco 8 kW, 208/240V, 1 Phase, 27. 75 kW 15 14. Also for: Oxbox j4ah4p18a1a00aa, Oxbox j4ah4p24a1b00aa, Oxbox j4ah4p30a1b00aa, Oxbox j4ah4p36a1b00aa, Oxbox Aug 27, 2018 · Everything Mentioned In This Video Available At https://www. The 30 amp has the blower and 1-5KW heater, the 60 amp has the other 10 KW of strip heat. High temperature limit Aug 7, 2024 · Ruud 7. Jan 11, 2012 · I have a Goodman aepf183016 and an hkr 15 cb heat strip. My furnace is in the attic and is sepperate from the ac unit. 1/31. Jan 10, 2014 · I went on a call to a heat pump we installed in 2007, when I got there only 1 leg of the heatstrip was energizing, I changed both sequencers, and all 4 came on, but they were each (5kw) drawing 30 amps, I still dont know exactly whats going on, I visually inspected the coil set, no shorts, or signs of heat, tried it with blower door off, and on. Provides emergency heat for your MRCOOL Universal air handler. 3 0. Introduction A. This would require a dedicated circuit using AWG # 10 wire on a 30 amp breaker. Understanding the differences between 5kw and 10kw heat strips is essential for making an informed decision that aligns with your heating needs and budget. Jul 24, 2019 · We will be replacing our complete AC / heat pump system (outdoor unit and inside air handler and I wanted to ask what is the proper size breaker size? We are going with a Goodman 2. 6 www. (240. Only two of the heat strips are glowing, I don't think the other 3 are doing anything. Leaving the control box to the machine/element I have about the same - 41amps. goodmanmfg. A partially melted lug is a bad sign. It is wired (from the disconnect) with AWG #8 wire I think. The heat strips are designated 40a per May 8, 2019 · However, the fields wiring requirements for the install require a 60 amp breaker for both branch circuits and NEC 424. The HNRD8-D is capable of 25,001 - 30,000 BTU of heating Lennox ECBA25-10CB, 10 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. ly/GoodmanHeatstr Order Online or Call (888) 474 - 9966; Mon - Fri 9:00am - 3:00am EST - Se Habla Español Sat - Sun 9:00am - 6:00pm EST 10 Kilowatt Electric Heat Kit for MRCOOL Universal Air Handlers; SKU: MHK10U: Weight (in lbs) 9. 6 kw and that the existing #4 aluminum wire I have, which carries 55 amps is sufficient for the 10 kw (9. 00 to 19. 5 kW coil will provide 32,415 BTUs of heat. It only has 14/2 wire ran to the inside unit from the breaker box and is on a 30 amp breaker. 5 heat pump in my home with a 10kw heat strip. 95 Current price is: $139. 5kw 17,000 Btu's 7Kw 24,000 Btu's 8Kw 27,000 Btu's 10Kw 34,000 Btu's 12Kw* 41,000 Btu's* 15Kw 51,000 Btu's 17kw* 58,000 Btu's* 20Kw 68,000 Btu's Aug 9, 2017 · Goodman 20 Kw Electric Strip Heat Kit with Circuit Breaker HKSC20DB. Let’s solve two examples to illustrate how you can calculate what size heat pump you need manually and via the calculator: What Size Heat Pump Do I Need For A 2,500 Square Foot House? (Example 1) Feb 28, 2012 · Given some of the figures Table 1 gives, to follow NEC 1 or both breakers in the panel may have to be changed to smaller breakers from the standard 60/30 for 15kw and 60/60 for 20kw. Jul 4, 2023 · Example of Heat Strip Size Calculation. -Sale! HEAT STRIP With Breaker 5KW FOR ICP, Carrier, Bryant, Payne AIR HANDLE $ 169. 125% of that is 78A, so I'll need an 80A breaker in the main panel. Also I am running one feeder and using the tap rule to tap a #10 thhn for 5kw heat strip on 30A breaker in unit and #6 thhn for 10KW heat strip on 60A breaker in unit. MRCOOL heat kit is the compatible heat kit model for MRCOOL MDUI18024 and MDUI18036 is capable of 25,001 - 30,000 BTU of heating capacity 8 kw 2-3 Ton Heat Strip 10kW = 10000W. Be confident with a 10-year unit replacement limited warranty and lifetime compressor limited warranty. What size breaker do you need for a 10kw heat strip? 10kw thermal bands are often 9. Aug 9, 2019 · In the process of installing a 5 Ton unit. Standard features of the Goodman Heater Coils include sequencers for better temperature control, multiple branch circuit capabilities and rust-resistant nickel chromium heat elements. com Need A Heat Strip? Click Link To Our Online Store: http://bit. 99 Get the lowest price on a 10kW Electric Heat Kit for Bosch Air Handler - WARMEHK100B - Fast Delivery, Lifetime Tech Support, & Free Shipping on most items. HNRd15-D Heat Kit is the compatible heat kit model for MRCOOL MDUI18048 and MDUI18060. I don't know what Bryant puts for breakers in their heat kits but their specs say max breaker for 15kw is 60/25 and 20kw is 60/50. Integrated Circuit Dec 27, 2017 · Heat strips are added in by the hvac contractor. On top of that, we include a Circuit Breaker Size Calculator further on (just insert watts and volts, and you get the correct breaker size). However, knowing the right size for an 8 kW heat strip can be a bit tricky. 866. The exact amps an electric furnace requires is solely based on the size of the furnace and its performance capabilities; however, typically electric furnaces require a draw between 60 and 80 amps. 5 0. 3. 4. 6 kw). 5 ton heat pump with a 10kw heat strip. Selecting the most appropriate heat strip size Jan 8, 2014 · I have 2. Nov 5, 2021 · Hey folks! I am now going to be installing a disconnect and Circuit Breaker (CB) for a 15KW heat strip (heat strip only, no other load). If you decide to keep the AL wire, then make sure the breaker is rated for AL. The booklet says max overlaod protection @240v is 45 amps or @208 is 40 amps. 0 ASPT 25B14AA 1 640 585 580 545 510 490 410 Table of motor kW to cable size chart is prepared based on the direct online start and star-delta starting. Mr Cool DIY Multi-Zone Breaker Sizes (20A, 25A, 30A) Feb 24, 2016 · OCP is 83A so Code says if not a standard size fuse you need to go up to next standard size. I was told the 10 kw heat strip for the Trane system I was proposed is really 9. Aug 9, 2017 · 8 Kw Goodman Electric Strip Heat Kit with Circuit Breaker HKSC08XC - Amazon. f is expressed in terms of percentage then it is first converted into units by dividing percentage power factor by 100 and then its value is given in the formula. 20 Amps. Amps = Watts/Volts, 8000/240 = 33 amps. Min. 5 tons Heat Pump - Use a 10 Kw 2. Please note that this unit requires one 60 amp breaker to function, and that this item cannot operate independently from a compatible ACiQ unit. Heating Capacity: 65,001 BTU/H – 70,000 BTU/H. I have it already mounted in the unit and the wire run to the load center. MRCOOL Heat Kit is the compatible heat kit model for MRCOOL MDUI18048 and MDUI18060. Total Amps = Watts divided by Volts), shouldn’t a 240V strip use 33. We have researched this question for you, and here is what we found. You need to get an evaluation from a professional. 5 ton heat pump setup in Northern Virginia (DC Suburbs) He put a 20KW heat strip kit in. They use the same base unit and depending on the size needed they install the proper kw strip. com SS-GASPT Airflow Data Model Speed Tap Static Pressure (in w. 5 - 2. Oct 8, 2021 · Provides Emergency Heat for your MRCOOL Universal Air Handler. We have a 3. Goodman. 0 - 5. The backup heat unit is divided into two internal circuits with three elements each. This is based on the heating capacity of 65,001 BTU/H to 70,000 BTU/H and the voltage of 208V/230V. Of course, read the label and identified that there are (2) 240v circuits required. The MHK15U is capable of 50,001 - 55,000 BTU of heating Jan 25, 2014 · Heat strip would be sized to 80% of 27,230 = 21,790 BTU/HR = 6 kW per ACCA Manual J practice. Installing a 25amp breaker or a 20 amp breaker should spare you the trouble. This is the maximum size. MOPs are accordingly 60 and 50. Goodman 20 Kw Electric Strip Heat Kit with Circuit Breaker (New Models Only) is available to buy in increments of 1 Description The Goodman HKTS Electric Heat Kits are made for Goodman and Amana air handlers. The MHK15U is capable of 30,001 BTU - 35,000 BTU of heating capacity to keep you comfortable through the winter months. com 15 Kw Goodman Electric Strip Heat Kit with Circuit Breaker HKSC15XB. 25 to 15. You may be thinking: But if we do some calculations to convert 8kW to amps (i. Legally and the electrical code stated that conductors can only be loaded to 80% of their rated capacity. He mentioned maybe using 4 gauge or 6 gauge Romex. The current system is on a 60 amp breaker and the HVAC guy said the current system has a 15kw heat strip. 3 Amps, With Breaker. Circuit Breaker Size % and Amps Charts. This is only for the heat strip of a heat pump model number in the link below. 95. For residential air handlers, heat strips range in size from 3kW to 25kW. com Jun 24, 2022 · The importance of breakers in electrical systems cannot be overemphasized. HO specifically stated he wanted 20 kW heat strips. 2 k@ wth 150F limit X All Cabinet Sizes 20 19. May 14, 2024 · SKU: S1-6HK16501506 Categories: Heat Kits, York Tags: 15 kw, 15 kW Electric Heat with Circuit Breaker, Electric Heat Kit for York Systems, Electric Heating Kit for HVAC, heat kit, heat strip, Heating Kit with Circuit Breaker, HVAC Electric Heating Upgrade, s1-6hk, S1-6HK 15 kW Heat Strip, york, York Electric Heater Kit, York Heat Element The size of a breaker is determined by the amp draw. kW 15 14. Dec 13, 2014 · Most air handlers with 15 KW of strip heat. HNRdX-D Heat Kit is the compatible heat kit model for MRCOOL MDUI18024 and MDUI18036. To find the amperage of a 8 kW or 8000 watt strip heater the following formula is used. Minimum circuit ampacities are 57 and 50 amps respectively. We would run #2 SEU copper. Brand. His reasoning was: 1) Thats what was there before and the breakers were sized to take that large of a heat kit 2) If you ever loose your outdoor unit you will be glad its there RXBH Series 20 kW Single Phase Electric KW Heat Strip Fast # Part # RXBH24A20J; Item # 2500492; Manufacturer Part #RXBH-24A20J 4. e. Previous electrician ran a 2 cdr 4 awg 1 cdr 6awg NM copper wire for this install. 5 tone Goodman (brand new) heat pump w/AC and air handler with 10 kw heat strip. The old Goodman had 60 amp breakers but perhaps it had a 10 KW strip. 95 Current price is: $169. For a 20 KW furnace, you’ll typically need an 83. Multiple branch circuit capability. EHK15AKB* 15 kW, single phase, with circuit breakers ALL† EHK15AHN 15 kW, 3--phase, no internal circuit protection ALL† EHK18AHN 18 kW, 3--phase, no internal circuit protection 4800, 6000 EHK20AKF 20 kW, single phase, with fuses ALL† EHK20AKB* 20 kW, single phase, with circuit breakers ALL† EHK25AHCF Sep 22, 2023 · Wire sizes are based on amperage. 8, 0. Each of the two circuits draws 31. So far, we've covered: A breaker's function within a circuit; How to size a breaker based on load and the reverse example (watts from breaker size); and; How to calculate circuit breaker and wire size. Current Rating. c) 0. My questionI know we have to follow the manufactures specs. Apr 29, 2022 · What size breaker for 20 kw electric furnace with #6? Stated with more detail, what size circuit breaker is needed for a 20 kW electric furnace wired with #6 wire, aka 6 AWG wire? Here is a quick answer – but an electrician should make the final determination. Pack Size As you can see, the DIY series uses 20A, 25A, and 30A. Share: Apr 30, 2008 · This is a "continuous load" so the wires must have an ampacity of 125% of 41. 5 Ton - 5 Ton Universal Series Split System Air Handlers Built-In Circuit Breaker. 00 kW 8 7. com 8 Kw Goodman Electric Strip Heat Kit with Circuit Breaker HKSC08XC. Completely assembled and tested including a plug in wiring harness for ease of installation in Air Handlers. 3-amp breaker when operating at 240 volts. Coldest winter climates (Average low winter temperatures of -10 degrees 20kW = 20000W. What Size Breaker Do I Need for A 20 KW Furnace. $ 149. 3 out of 5 stars 8 ratings. Experience uninterrupted warmth with 10KW of reliable backup heating at your fingertips. 0 kW HKR * Heat kit requires three-­‐phase power supply AA 6,7 Provides Emergency Heat for your MRCOOL Universal Air Handler. Oct 29, 2012 · This tutorial will teach you how to properly size your wire for electric heat strips using the SuperCool Slide Rule. 00 kW 20 19. Click to Zoom Nordyne 922529 - 20 Kw Heat Strip Kit, 922529- 922529 is an official OEM 20 Kw Heat Strip Kit for Nordyne HVAC equipment. The wire from the breaker to the disconnect is AWG #6. I was told the capacity of the #4 wire is 55 amps and The 9. 5 Kw Ruud Electric Strip Heat Kit with Circuit Breaker Dec 2, 2021 · When buying a new heat pump, you will likely need to choose a heat strip size. 0 tons Heat Pump - Use a 20 Kw. Auxiliary heat (one 3 kW strip operating) would typically be necessary at > 22'F and < 34'F 6 days ago · Electric heat strips, emergency heat strips, and auxiliary heat strips offer supplemental heat sources within the HVAC system, providing efficient heating solutions. f) is given in form of unit, ranging from 0 to 1 (for example: 0. I live in Nebraska if that matters. The box is about 25-30 ft from the furnace. The size of […] You can see for the heat pump size table that, for example, a 2,000 sq ft house requires around 60,000 BTU or a 5-ton heat pump. Produces 68,200 BTUs of heat. Lennox ECBA25-20CB, 20 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. I think this is because the other heat strips are connected to the two other 60 amp breakers which have no power. 5Amps 5. Can often use a 60 amp and 30 amp circuit. Number of Phases. 5 kW / 208 V = 24 A, as he said. 7 0. 45 Amps. The kW rating of a heat strip corresponds to its energy consumption and heat output (with 1 kW being roughly equivalent to 3,412 BTUs of heat). www. Crafted to seamlessly Feb 12, 2019 · Are you increasing the size of all of your duct work to use a 20 KW strip heater? Why are you up sizing the heat kit, did you add on to the house? For 20 KW, it would be 2-6/2 wire runs, and 2 60amp double pole breakers. Cat # : 16Y43 Model/Part # : ECBA25-12. Jan 3, 2011 · My house is 1100 sq ft and my furnace is 10kw. Severe cold weather may mean you need a good heat strip for your Goodman air handler or package unit. Max Fuse Breaker: 60 Amp…. HEAT STRIP With Breaker 8KW FOR ICP, Carrier, Bryant, Payne AIR HANDLE $ 199. Example: Mr Cool DIY 24k breaker size is 25 amps. 4A. (By the way, the extra 1000 in your equations is incorrect. 208V/230V. 5, 10, 15, 20, and 25 kilowatts. A plug-in wiring harness allows for easy installation into a compatible air handler. At the end, we also included the ‘just tell me the breaker size I need’ Breaker Size Chart that tells you what breaker size you need for devices with different wattages (from 50W units to big 20,000W Mar 2, 2013 · The 10kw heat strip called for a 60amp circuit breaker and I have a 50amp stab-loc breaker in a 200amp Federal Pacific Electric panel from the mid 1960s when the house was built. I always pull #8 thhn on 40 amp breaker because the strips are rated 7500 watts @240v 31 amps, add 125% for continuous load (which i dont think they would be continuous because they are aux heat strips) and im still under 40 amps. Mention 3. I ordered a 15 kw heat strip and need to know what size breaker and wire to use. Snip off the thin 18 gauge metal strip between the two element slots A160002 Fig. Built-in overcurrent protection on all units as indicated in electrical data chart (see spec sheet). Model# BAYEVAC10LG--anyone have the specs? kW F Three Phase 208/240 V* 05 4. 9 1. $ 169. The HNRD5-D is capable of 15,001 - 20,000 BTU of heating Jan 17, 2019 · The only thing that bothers me is the heat strip sizing. I'm master electrician and planning to wire both units myself. Dec 20, 2018 · With a heat pump system the air handler houses the emergency heat strips and the wiring needs to be sized for it Sent from my RCT6213W22 using Tapatalk My electrical answers are based on 2017 NEC, you may have local amendments. Each element is apparently driven with 208 V accross it and is drawing 5 kW of power. Yes. 7kW for 7. - Save time when you speak with one of our experts 1. For 5-- through 20--kW circuit breaker models: After installing heater assembly, attach circuit breaker as-sembly to unit with screws provided. com HEAT STRIP With Breaker 10KW FOR ICP, Carrier, Bryant, Payne AIR HANDLE $ 199. Call us at 1-270-575-9595 or start a chat session. The heat strip is actually 14,400 watts 208/230 volt. I am wondering what size of wire to run to the Unit. Min Circuit Ampacity: 50 Amp. : MAYHTR1A08BKRA Dec 13, 2013 · The heat strips calls for MOPD 60A and MCA 52. 50 kW * A 1 2 3 4,5 11 HKR * -­‐05 Unit Type Revisions HKS Heat Jan 25, 2019 · Goodman HKP-05C Packaged Units Electric Heat Kit ; Circuit Breaker ; Heating: 0 BTU 5 kW, Cooling: 0 BTU, 208/240 V 1 Phase ; Register your new Goodman unit for enhanced warranty coverage at no cost. Feb 3, 2014 · What size wires and breakers are needed for the correct installation of a 15kw and 20kw electric heat strips for an - Answered by a verified Electrician We use cookies to give you the best possible experience on our website. For rooftop or ground-level horizontal installation and applications. Completely assembled and tested. Aug 9, 2017 · 15 Kw Goodman Electric Strip Heat Kit with Circuit Breaker HKSC15XB - Amazon. " Should pop up, especially if it's a new install. I = W/E. 6 kW C C Cabinet 15 14. 6/2wg to 60 amp and 10/2wg to the 30 amp ?If so do I need 2 disconnects? Aug 8, 2023 · In this post, we’ll talk about the specifics of breaker sizes, helping you find the perfect match for your 20 KW furnace. Reference info: Bosch OEM Reference No. KW: 10, circuit breaker included. 22 requires heaters to have 60 amp overcurrent max. Element size Heating output . 2- 60 amp breakers is usually for a 20 kw unit. MRCOOL is the compatible heat kit model for MRCOOL MDUI18048 and MDUI18060 is capable of 65,001 - 70,000 BTU of heating capacity to keep you comfortable through the winter months. Featuring: electric heat limit control, rust resistant nickel chromium heating elements. : EHK08B; Ameristar OEM Reference No. It is currently only producing 83 degre F at the registers with it 17 degrees outside. 4B) 240. 2 0. 4 kW D D Cabinet 19 19. For a 15kw unit you usually see a 60 amp and a 30 amp breaker. OXBOX J4AH4P Series air conditioner pdf manual download. 9). 4). This product code is for residential, single phase heaters ONLY. 95 Current price is: $149. When I install the heat strip (hvac work is not my thing) and its circuit I am pretty sure that becomes the circuit that powers the air handler and of course heat strips, despite the fact it says maximum ocp of 15 amps. the problem is HEAT on the conductor 5K with 240v can pull over 22 amps, and undersized wire, with crimp connectors, with sequencers and other points of resistance and you can easily overtemp a 30 amp breaker. 2. I was informed that the 10 kw is really 9. The HNRD10-D is capable of 30,001 - 35,000 BTU of heating capacity to keep you comfortable through the winter months. Do I need to supply separate conductors to each breaker )ie. My contractor is on vacation † These heaters are Intelligent Heat capable when used with the FK4, FV4, and 40FK fan coils and corporate 2-speed programmable thermostat (TSTATXXP2S01-A), or ThermidistatTM Control (TSTATXXPRH01-B). Jan 19, 2022 · MRCOOL® Electric Heat Kit mrcool. Another question is the heat strip he sold me being 15 kw isn’t listed on the unit. Again, replacing the breaker will be cheaper than running all new copper. 4 0. If all else fails and you don't wanna risk it, Google the model number and "manual. Cat # : 16Y46 Model/Part # : ECBA25-20CB Mar 18, 2015 · Looking for validation or correction on my understanding of requirements for wiring 5 ton Trane air handler with 20kw heat strips. com Oct 2, 2013 · 15 Kw Goodman / Amana Electric Strip Heater With Circuit Breaker - HKSC-15XB Goodman HKSC15XA 14. HNRd20-D Heat Kit is the compatible heat kit model for MRCOOL MDUI18048 and MDUI18060. Was planning to use this 6/2 wire that we already ran, but stumbled across a reference that stated 20 kW should use 4 gauge. Like magic, an expert will be able to help you navigate our website and place items directly into your shopping cart. ) 4. ykv cgs sjvwhw zzvd gybpn bgmw xstexh lqw cdlcaxv knst